Kontrol Kualitas
Rumah / Tentang Kami / Kontrol Kualitas

Indicator Lights

Models: 0008, 0012, 0016, 0068, 0069, 0102, 0120, 0141, 0145, 0160, 0180, 0275, 0276, 0281, 0295, 0568, 0589

Our indicator lights are UL Recognized Components (RU mark upon authorization) under UL File No. E513209. Tested to safety standards UL 496 (US) and CSA C22.2 No.43 (Canada). This component‑level approval is intended for factory‑mount integration into complete OEM end‑equipment. The final safety acceptability of end‑products shall be determined by UL evaluation of the full finished device.

  • Electrical Rating: Neon lamp, 50/60Hz, Max. 0.5W
  • Housing Plastic: Minimum V‑2 flame rating, RTI ≥125 °C, passed 125 °C / 7‑hour mold‑stress‑relief test
  • Important Note: This is component‑level recognition, NOT UL‑Listed for standalone end‑use. Only factory‑installation is permitted; field‑installation is not allowed.

Appliance Switches

Models: 8300 series, 8301 series

8300 series and 8301 series appliance switches hold UL Certificate of Compliance.

  • Certificate Number: UL‑US‑2408673‑0
  • Report Reference: E534983‑20240228
  • Issue Date: 2024‑02‑29

Representative product samples have been tested in accordance with current UL requirements.

Certificates and test reports for both product lines are available upon request for your OEM project review.

Shenzhen Arcolps Electronic Co., Ltd. kontrol kualitas 0Shenzhen Arcolps Electronic Co., Ltd. kontrol kualitas 1

  • Cina Shenzhen Arcolps Electronic Co., Ltd. Sertifikasi
    UL认证